AERIAL BUNDLED CABLES (ABC CABLES)
Download Catalogue for ABC Cables
POWER CABLES
- XLPE CABLES
XLPE cable for underground use 6~35kV XLPE insulation armour power cable Cable Construction: Conductor:Al or Copper Wire Rated Voltage:6~35kV Insulation:XLPE Inner sheath:PVC Armour:SWA(fine or thick galvanized steel wire) ,STA(galvanized steel tape ),AWA(aluminium wire) Outer Sheath:PVC or PE XLPE cable Application XLPE cable of XLPE cable is mainly Can be laid in verticalsection,indoor, tunnelsand mines. cable can bear outer machanic force and very large tractional force. XLPE cableGeneral Characteristics XLPE cable is suitable for use in rated AC voltage (Uo / U) 6/6 ~26 / 35kV system transmitting and distributing lines. According to different sheath make ups, they can be used for layingin the air (cable bridges,indoor wall supponts and groove boxes) and in soil (direct burying, cable canals and pipelines, etc.) XLPE cable has anumber of advantages overpaper insulated and PVC insulated cable.XLPE cable has excellent electric property, mechanical property, high ageing resisting, environmetal stress resisting anti-chemical corrossion, and it is simple construction, using convenient and higher operating of long term temperature.It can be laidwith no drop restriction.Various offlame-retardant andnon-flame retardant XLPE cable can be manufacturedwith three technology (peroxide, silance and irradiation crosslinking). The flame-retardant cable covers all kinds of low-smoke,low-halogen, low-smoke halogen free,and non-smoke nonhalogenated and three classes ofA, B, C. Our XLPE cable can be manufactured according to company’s specification which is equivalent to IEC60502,IEC 60 332, and IEC 60 754. Some of indexes are superior to above international standard IEC.Some of special XLPE cable can be manufactured according to the other standards required by customs.
XLPE cable having higher long-term working temperature and greater current rating, at the same environment XLPE cable may be reducedsize (nominal cross-section) 1 or 2 class in comparison with paper and PVC cable. This is not only improve the quality and properties of products, but also reduce cable’s production costs. XLPE cableApplication This series of XLPE cable is mainly laid underground. Cable can bear outer machanic Force. but power cable shouldnot bear large tractional Force. General Characteristics This product is suitable for use in rated AC voltage (Uo / U) 6/6 ~26 / 35kV system transmitting and distributing lines. According to different sheath make ups, they can be used for layingin the air (cable bridges,indoor wall supponts and groove boxes) and in soil (direct burying, cable canals and pipelines, etc.) XLPE insulated power cable has anumber of advantages overpaper insulated and PVC insulated cable.XLPE cable has excellent electric property, mechanical property, high ageing resisting, environmetal stress resisting anti-chemical corrossion, and it is simple construction, using convenient and higher operating of long term temperature.It can be laidwith no drop restriction.Various offlame-retardant andnon-flame retardant XLPE cable can be manufacturedwith three technology (peroxide, silance and irradiation crosslinking). The flame-retardant cable covers all kinds of low-smoke,low-halogen, low-smoke halogen free,and non-smoke nonhalogenated and three classes ofA, B, C. Our XLPE cable can be manufactured according to company’s specification which is equivalent to IEC60502,IEC 60 332, and IEC 60 754. Some of indexes are superior to above international standard IEC.Some of special XLPE cable can be manufactured according to the other standards required by customs. XLPE cable having higher long-term working temperature and greater current rating, at the same environment XLPE cable may be reducedsize (nominal cross-section) 1 or 2 class in comparison with paper and PVC cable. This is not only improve the quality and properties of products, but also reduce cable’s production costs.
- PVC CABLES
PVC insulated
Multi-core, Al or Cu conductor, armored or unarmored PVC insulated, PVC sheath.
standards: IEC, BS, DIN etc.
PVC Insulated PVC Sheath Power Cable
Low Voltage (0.6/1 KV)
Single crore or Multi-Core
Copper or aluminium Conductor
PVC Insulation/Steel Tape Armored or galvanized steel wire armored or unarmoured
PVC Outer Sheath Power Cable.
The Products are Mainly Complying with the IEC60502 Standard, Also Can be produced according to OEM Requirements and Other Standards, Such As BS, DIN, ASTM, AS, NFC, GOST standards etc.
The Conductor Long time permissible operating temperature should be more than 70 Degrees and in short Circuit, its high temperature should be not more than 165 degrees.
Laying Cable is not Restricted with its altitude, easily installed above zero Degree, and widely used in transmission and distribution.
Other Special Characteristics: Design and manufacture according to customers’ request.
- RUBBER CABLES
5KV/8KV/15KV/25KV shielded flexible power cable are intended for flexible connection to electrical equipment.
APPLICATION:
Rubber insulated and sheathed cables are suitable for both indoor and outdoor use in industrial and agricultural plant and on construction sites. Flexible cables are also suitable for areas of medium mechanical stress and can be used in hot, cold, damp environments or in temporary immersion in water. They are also oil resistant.
CONSTRUCTION:
Conductors : Plain copper wire / tinned copper wire.
Insulation: EPR rubber.
Sheath: Synthetic Rubber / neoprene rubber
Minimum Bending Radius: up to 25mm2 6D
MAXIMUM CONDUCTOR TEMPERATURE: 105°C.
CURRENT RATING:
<4mm2 Table 4H3A, 4H3B in BS 7671 or on page 103
>4mm2 Table 4H1A in BS 7671
- CONTROL CABLES
Type | Name | Section Area(mm2) | No. of Core |
KVV | Copper Conductor, PVC Insulated and Sheathed control cable | 0.75 1.0 1.5 2.5 | 2-8,10,12,14,16,19,24 27,30,37 |
4.0 6.0 | 2-8,10,12,14 | ||
KVVP | Copper Conductor, PVC Insulated and Sheathed, Copper-braid Screened Control Cable | 0.75 1.0 1.5 2.5 | 2-8,10,12,14,16,19,24 27,30,37 |
4.0 6.0 | 2-8,10,12,14 | ||
KVVP2 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | 0.75 1.0 1.5 2.5 | 2-8,10,12,14,16,19,24 27,30,37 |
4.0 6.0 | 2-8,10,12,14 | ||
KVVP2-22 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Steel-tape armored Control Cable | 0.75 1.0 1.5 2.5 | 2-8,10,12,14,16,19,24 27,30,37 |
4.0 6.0 | 2-8,10,12,14 | ||
KVV22 | Copper Conductor, PVC Insulated and Sheathed, Steel-tape armored Control Cable | 0.75 1.0 1.5 2.5 | 2-8,10,12,14,16,19,24 27,30,37 |
4.0 6.0 | 2-8,10,12,14 | ||
KVVR | Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable | 0.75 1.0 1.5 2.5 | 2-8,10,12,14,16,19,24 27,30,37 |
4.0 6.0 | 2-8,10,12 14 | ||
KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable | 0.75 1.0 1.5 2.5 | 2-8,10,12,14,16,19,24 27,30,37 |
4.0 6.0 | 2-8,10,12,14 |