{"id":39,"date":"2013-10-26T22:13:35","date_gmt":"2013-10-26T19:13:35","guid":{"rendered":"http:\/\/en.pegumba.com\/?p=39"},"modified":"2014-07-21T18:01:10","modified_gmt":"2014-07-21T15:01:10","slug":"cables","status":"publish","type":"post","link":"http:\/\/en.pegumba.com\/?p=39","title":{"rendered":"KIOSK (KTP) &#038; SUBSTATION"},"content":{"rendered":"<p><strong>KIOSK (KTP)<\/strong><\/p>\n<p>PEGUMBA KIOSKS (KTP) are mostly manufactured for Turkmenistan and Uzbekistan Markets\u00a0according to European Standards.<\/p>\n<p><a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/KTP-2.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/KTP-2-300x156.jpg\" alt=\"KTP-2\" width=\"300\" height=\"156\" \/><\/a>\u00a0<a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/KTP-3.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/KTP-3-300x198.jpg\" alt=\"KTP-3\" width=\"300\" height=\"198\" \/><\/a><\/p>\n<p>The main purpose of KTP is to\u00a0supply electric energy for schools, hospitals, governmental buildings and rural locations within temperature values -55 \u00b0 C &#8211; +55 \u00b0 C.<\/p>\n<p><a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/3.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/3-300x200.jpg\" alt=\"3\" width=\"300\" height=\"200\" \/><\/a>\u00a0<a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/KTP-4.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/KTP-4-300x219.jpg\" alt=\"KTP-4\" width=\"300\" height=\"219\" \/><\/a><\/p>\n<p>Major Types of KTP are classified as below.<\/p>\n<p>KTP-40,\u00a0KTP-63,\u00a0KTP-100,\u00a0KTP-160, KTP-250, KTP-400, KTP-630, KTP-1000 and KTP-1600.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/4.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/4-300x200.jpg\" alt=\"4\" width=\"300\" height=\"200\" \/><\/a>\u00a0<a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/5.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/5-300x200.jpg\" alt=\"5\" width=\"300\" height=\"200\" \/><\/a><\/p>\n<p><strong>General Features of KTP<\/strong><\/p>\n<p>KTP is a kiosk-type package transformer substations deadlock or transmission type . Equipment is designed to accept a three-phase AC power frequency and voltage 6 (10 ) kV and converting it into an electric current with a voltage of 0.4 (0.23 ) kV , and the subsequent supply of consumers. Power from 40 kVA up to 1600 kVA , voltage &#8211; 10 (6) \/ 0.4 (0.23) kV . The substation is designed for outdoor installation has on the high voltage side air or cable entry on the side of low voltage as air or cable outlet .<\/p>\n<p><a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-5.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-5-300x225.jpg\" alt=\"\u041a\u0422\u041f-5\" width=\"300\" height=\"225\" \/><\/a>\u00a0<a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-1.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-1-219x300.jpg\" alt=\"\u041a\u0422\u041f-1\" width=\"219\" height=\"300\" \/><\/a><\/p>\n<p>KTP kiosk-type can be used to supply consumers of agricultural , industrial use , as well as communal facilities in the schemes of radial distribution networks and ring type .<\/p>\n<p><strong>Recommended operating conditions :<\/strong><\/p>\n<p>Relative humidity (at a temperature of 20 \u00ba C + ) &#8211; 80 % ;<br \/>\nOutdoor air temperature &#8211; from &#8211; 45 \u00ba C to 40 \u00ba C;<br \/>\nAltitude up to 1000 m ;<br \/>\nAllowed ice thickness up to 20 mm.<br \/>\nMaximum wind speed &#8211; up to 36 m \/ s in case of icing &#8211; up to 15 m \/ s;<br \/>\nFor stable operation of the KTP kiosk type requires that the surrounding air does not contain dust, corrosive vapors and gases that can have a devastating impact on the insulating material and metal.<\/p>\n<p><a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-2.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-2-165x300.jpg\" alt=\"\u041a\u0422\u041f-2\" width=\"165\" height=\"300\" \/><\/a>\u00a0<a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-4.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-4-187x300.jpg\" alt=\"\u041a\u0422\u041f-4\" width=\"187\" height=\"300\" \/><\/a><\/p>\n<p>Insulation resistance value indicators on the HV side to ground elements.<\/p>\n<p>When calculating the type and depth of the marks under the foundation of QFT to the exact terms of accommodation. In the case of columnar foundation Bookmarks distance between the individual columns must not exceed 1.1 m<\/p>\n<p><a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-3.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-3-225x300.jpg\" alt=\"\u041a\u0422\u041f-3\" width=\"225\" height=\"300\" \/><\/a>\u00a0<a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-6.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-6-227x300.jpg\" alt=\"\u041a\u0422\u041f-6\" width=\"227\" height=\"300\" \/><\/a><\/p>\n<p><strong>The structure of KTP kiosk type includes:<\/strong><\/p>\n<p>Bay to accommodate the power transformer ;<br \/>\nSwitchgear on HV side &#8211; RU HV ;<br \/>\nDispenser on the LV side &#8211; RU LV .<br \/>\nEquipment included in RU HV KTP dead-end type with cable entry capacity from 400 kVA to 630 kVA &#8211; fuses and switches , with cable entry capacity from 100 kVA to 250 kVA &#8211; disconnector and fuses , with air input &#8211; fuses ;<\/p>\n<p>In picking passage substations with capacity from 250 kVA to 630 kVA &#8211; series load switch , then disconnect switch with fuses and switches , with a capacity of 100 kVA to 160 kVA &#8211; consistently isolator , then disconnectors with fuses and disconnector ;<\/p>\n<p>According to GOST 12022 power transformer compartment allowed installation of the power equipment such as oil TM and TMG with a capacity of up to 630 kVA (inclusive).<\/p>\n<p><a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-7.jpeg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-7-184x300.jpeg\" alt=\"\u041a\u0422\u041f-7\" width=\"184\" height=\"300\" \/><\/a>\u00a0<a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-8.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/\u041a\u0422\u041f-8-166x300.jpg\" alt=\"\u041a\u0422\u041f-8\" width=\"166\" height=\"300\" \/><\/a><\/p>\n<p><strong>Equipment included in the shield:<\/strong><\/p>\n<p>Automatically switches the type of outgoing lines in the form of circuit breakers with fuses ;<br \/>\nCircuit breaker or disconnecting switch input ;<br \/>\nPanel voltage control on the tires and 0.4 kV for electricity metering ;<br \/>\nSuppressors or arresters LV ;<br \/>\nAutomatic switch street lighting.<\/p>\n<p><strong>SUBSTATION<\/strong><\/p>\n<p>PEGUMBA Package Substations are metallic enclosures of multiple compartments that are interconnected but clearly separated.<\/p>\n<p><a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-232\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-3-300x225.jpg\" alt=\"package-3\" width=\"300\" height=\"225\" srcset=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-3-300x225.jpg 300w, http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-3.jpg 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a> <a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-230\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-1-300x266.jpg\" alt=\"package-1\" width=\"300\" height=\"266\" srcset=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-1-300x266.jpg 300w, http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-1.jpg 500w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><strong>Package Substation exists in 3 Compartment Structures in the following forms:<\/strong><\/p>\n<p>MV Switchgear \u2013 Transformer \u2013 MV Switchboard<\/p>\n<p>MV Switchgear \u2013 Transformer \u2013 LV Switchgear<\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Main Features<\/strong>:<\/span><\/p>\n<div>&#8211; Can integrate Air or SF6 insulated Ring Main Units with various configurations.<\/div>\n<div>&#8211; Can integrate Oil or Dry-type transformers.<\/div>\n<div>\n<p>&#8211; Integrated metering and protection (optional).<br \/>\n&#8211; Provisions for remote monitoring and control of switching devices on MV or LV compartments.<br \/>\n&#8211; High climate &amp; corrosion resistance.<br \/>\n&#8211; High operation reliability.<br \/>\n&#8211; Operating personnel safety.<br \/>\n&#8211; Easy installation of power transformer.<br \/>\n&#8211; Rapid Installation for under urbanization sites.<br \/>\n&#8211; Available with digital electronic locks which can be remotely controlled.<br \/>\n&#8211; All interconnecting equipment between Medium Voltage and Transformer and Low Voltage are factory tested.<br \/>\n&#8211; Adequate space for inspection and maintenance of transformer or capacitor banks (walk-in accessibility).<br \/>\n&#8211; Can be connected with SCADA system.<\/p>\n<\/div>\n<p><span style=\"text-decoration: underline;\"><strong>Design Standards:<\/strong><\/span><\/p>\n<p>Our Package Substations are manufactured according to the following IEC &amp; VDE standards<\/p>\n<p>&#8211;\u00a0\u00a0\u00a0IEC publication 62271-102.<br \/>\n&#8211;\u00a0\u00a0\u00a0IEC publication 60420<br \/>\n&#8211;\u00a0\u00a0 IEC publication 60265<br \/>\n&#8211;\u00a0\u00a0\u00a0DIN VDE 0670<\/p>\n<p><a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-main.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-229\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-main-300x224.png\" alt=\"package-main\" width=\"300\" height=\"224\" srcset=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-main-300x224.png 300w, http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-main.png 848w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a> <a href=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-231\" src=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-2-300x209.jpg\" alt=\"package-2\" width=\"300\" height=\"209\" srcset=\"http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-2-300x209.jpg 300w, http:\/\/en.pegumba.com\/wp-content\/uploads\/2013\/12\/package-2.jpg 650w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Suitable for the following applications:<\/strong><\/span><\/p>\n<p>&#8211;\u00a0\u00a0\u00a0Buildings<br \/>\n&#8211;\u00a0\u00a0\u00a0Real Estate Development Projects<br \/>\n&#8211;\u00a0\u00a0\u00a0Infrastructure<br \/>\n&#8211;\u00a0\u00a0\u00a0Industry<\/p>\n","protected":false},"excerpt":{"rendered":"<p>KIOSK (KTP) PEGUMBA KIOSKS (KTP) are mostly manufactured for Turkmenistan and Uzbekistan Markets\u00a0according to European Standards. \u00a0 The main purpose of KTP is to\u00a0supply electric energy for schools, hospitals, governmental buildings and rural locations within temperature values -55 \u00b0 C &#8211; +55 \u00b0 C. \u00a0 Major Types of KTP are classified as below. KTP-40,\u00a0KTP-63,\u00a0KTP-100,\u00a0KTP-160, KTP-250,&hellip;<\/p>\n","protected":false},"author":1,"featured_media":172,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-39","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"_links":{"self":[{"href":"http:\/\/en.pegumba.com\/index.php?rest_route=\/wp\/v2\/posts\/39","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/en.pegumba.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/en.pegumba.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/en.pegumba.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/en.pegumba.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=39"}],"version-history":[{"count":20,"href":"http:\/\/en.pegumba.com\/index.php?rest_route=\/wp\/v2\/posts\/39\/revisions"}],"predecessor-version":[{"id":281,"href":"http:\/\/en.pegumba.com\/index.php?rest_route=\/wp\/v2\/posts\/39\/revisions\/281"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/en.pegumba.com\/index.php?rest_route=\/wp\/v2\/media\/172"}],"wp:attachment":[{"href":"http:\/\/en.pegumba.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=39"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/en.pegumba.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=39"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/en.pegumba.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=39"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}